Specifications Lunaire
Stability / Shelf Life Test Chambers <<Go
Back
|
|
|
|
Lunaire Steady State and Food & Drug
Stability Chambers
Overall dimensions in inches/centimeters
| Model |
Non-humidified |
CEO
910-1 |
CEO
910-2 |
. |
. |
CEO
917-1 |
CEO
917-2 |
. |
. |
CEO
932-1 |
CEO
932-2 |
. |
. |
CEO
941-1 |
CEO
941-2 |
. |
. |
CEO
958-1 |
CEO
958-2 |
. |
. |
| . |
Humidified |
. |
. |
CEO
910-3 |
CEO
910-4 |
. |
. |
CEO
917-3 |
CEO
917-4 |
. |
. |
CEO
932-3 |
CEO
932-4 |
. |
. |
CEO
941-3 |
CEO
941-4 |
. |
. |
CEO
958-3 |
CEO
958-4 |
Work
Space |
W |
28/71 |
22.5/57 |
33/84 |
43/109 |
60/152 |
| D |
25/64 |
26/66 |
28/71 |
28/71 |
28/71 |
| H |
24/61 |
51/130 |
60/152 |
60/152 |
60/152 |
| Exterior |
W |
34/86 |
28.5/72 |
39/99 |
50/127 |
70/178 |
| D |
29/74 |
31/79 |
32/81 |
32/81 |
32/81 |
| H |
49.5/126 |
79/201 |
88/224 |
91/231 |
88/224 |
91/231 |
88/224 |
91/231 |
88/224 |
91/231 |
88/224 |
91/231 |
88/224 |
91/231 |
| No.
of Shelves |
2 |
4 |
4 |
4 |
8 |
| No.
of Shelf Guides |
7 |
16 |
19 |
19 |
38 |
| Note:
Casters add 3" to exterior height |
| Temperature Range |
| Low |
°C |
10°
above
ambient |
0 |
10°
above
ambient |
0 |
10°
above
ambient |
0 |
10°
above
ambient |
0 |
10°
above
ambient |
0 |
10°
above
ambient |
0 |
10°
above
ambient |
0 |
10°
above
ambient |
0 |
10°
above
ambient |
0 |
10°
above
ambient |
0 |
| High |
°C |
+99 |
+99 |
+99 |
+99 |
+99 |
+99 |
+99 |
+99 |
+99 |
+99 |
+99 |
+99 |
+99 |
+99 |
+99 |
+99 |
+99 |
+99 |
+99 |
+99 |
| Utilities |
| Refrigeration (HP) |
|
- |
. . |
- |
. |
- |
. |
- |
. |
- |
. |
- |
. |
- |
. |
- |
. |
- |
. |
- |
. |
| Heater Capacity |
1.5 KW |
1.5 KW |
1.5 KW |
2 KW |
3 KW |
6 KW |
| Humidifier |
KW |
- |
1.5 |
- |
1.5 |
- |
1.5 |
- |
1.5 |
- |
3 |
| GPH |
0.5 |
0.5 |
0.5 |
0.5 |
1.0 |
| AMPS @ 115V, 1 |
16.5 |
- |
21 |
- |
21 |
- |
- |
- |
| AMPS
@ 208/230, 4-WIRE, 1-60Hz |
|
- |
17 |
24 |
29 |
- |
20 |
26 |
32 |
- |
20 |
26 |
24 |
18 |
24 |
30 |
37 |
36 |
43 |
49 |
56 |
AMPS Breaker
Overcurrent production recommended |
20 |
20 |
30 |
40 |
30 |
30 |
40 |
40 |
30 |
30 |
40 |
30 |
30 |
30 |
40 |
50 |
50 |
60 |
60 |
70 |
| Unit Weight |
LBS |
350 |
475 |
400 |
550 |
550 |
675 |
600 |
750 |
1000 |
1300 |
1150 |
1350 |
1300 |
1600 |
1450 |
1650 |
1550 |
1850 |
1700 |
1900 |
Humidity capability: above ambient to 96% RH on -3 models; 20% to 96%
RH on -4 models. Based on ambient conditions of 22°C and 50% RH, limited
by a 5°C dewpoint temperature. Controll tolerance: ±0.3°C and ±2%after
stabilization.

|
| |