PRODUCT BRANDS: Tenney Industrial Ovens, Environmental Test Chambers and Rooms, Temperature Humidity Cycling Test Chambers Blue M Industrial Ovens, Environmental Test Chambers and Rooms, Temperature Humidity Cycling Test Chambers Gruenberg Industrial Ovens, Environmental Test Chambers and Rooms, Temperature Humidity Cycling Test Chambers Linderg Industrial Ovens, Environmental Test Chambers and Rooms, Temperature Humidity Cycling Test Chambers

Reach-in Temperature and Humidity Test Chambers

Tenney Classic Temperature Humidity Cycling Test Chamber

Benefits

  • Provides a wide range of temperature and humidity conditioning with many features for optimal tests
  • Uses environmentally friendly, CFC-free refrigerants and durable refrigeration systems
  • Hi-Lo pressure and oil pressure switches stop compressors from exceeding preset limit conditions, assuring safety of product and operator
  • Controllers feature advanced LCD display, allowing for fast and easy programming and configuration
  • Available in a wide range of sizes and models to meet specific testing needs

Features

  • Semi hermetic refrigeration system
  • Vertical recirculation conditioning system
  • Automatic defrost for door gaskets
  • Non-corroding parts on all humidity capable units
  • Low water protection
  • Open-air low mass nichrome wire heater elements supported by ceramic insulators
  • Single stage or cascade refrigeration system
  • Vapor-Flo I humidity generator (for capable units) with bell jar configuration

Performance

  • Control accuracy: ±0.3°C and  ±2% RH
  • Standard humidity conditions: 20% to 98% RH in the dry bulb range from + 20° to + 85°C, as limited by a 3° dewpoint.
  • Chamber models with a 'S' suffix indicate a single stage refrigeration system with one compressor.
  • Temperature control range: -40°C to +200°C,  ±0.3°C
  • Models TH27 and TH65 are single stage refrigeration systems with a smaller temperature control range: -20°C to +100°C, ±0.2/ ±0.3°C, respectively.
  • Chamber models with the 'C' suffix indicate a cascade refrigeration system and two compressors.
  • Temperature control range: -73°C to +200°C, ±0.3°C

 Controllers

Watlow F4 Temperature Controller

Watlow F4 Temperature Controller

  • Single Channel
  • Profiling: Forty Profiles, 256 Steps
  • Automatic & Manual Control
  • 1 Input: Universal Type (RTD is Std.)
  • 4 Digital Inputs
  • 2 Auxiliary Analog Inputs - Optional
  • 2 Control Outputs: Time Proportioned, On/Off, or 4-20 ma
  • 2 Alarm Outputs
  • 8 Digital Event Outputs
  • 2 Retransmit Outputs - Optional
  • Communications: EIA-232 and EIA-485 with Modbus RTU protocol
Heat Limiter- Temperature Actuated Thermal Cutoff

Heat Limiter- Temperature Actuated Thermal Cutoff

  • Axial leaded one-shot protection device
  • For chambers with limit of 200 degrees C, limiter opens up when surrounding temperature reaches 240 degrees C

Photo Gallery

Tenney Classic Family

Options

Watlow LV Controller

Watlow LV Controller

  • Protects against product over/under temperature
  • microprocessor based controller that incorporates programmable high and low temperature limits
  • 100 ohm Platinum RTD used for temperature measurement
  • easy to use

Watlow EZ Zone PM (PID)

  • Single channel ¼ DIN non-profiling type controller
  • Type J thermocouple for temperature measurement
  • Fully programmable menu system
  • Auto Tune is provided for fast, efficient start ups
  • EZ-Zone® configurator software is provided on a CD
  • Watlow standard bus communications is provided for the EZ-Zone configurator software only
LinkTenn 32 Controller Software

LinkTenn 32 Controller Software

  • Monitoring & control of multiple controllers/chambers
  • Alarm reporting and notification via email or fax
  • User-friendly profile program editor
  • Logging, printing and graphing of process data
  • Exporting of logging history data via CSV file for easy import into Microsoft Excel or analysis packages
Chart recorder

Chart recorder

  • Circular or strip type
  • Records temperature versus time
  • Some models include digital display
  • J thermocouple for temperature measurement
GN2 Purge System

GN2 Purge System

  • Provides inert atmosphere inside the chamber
  • Minimizes moisture buildup
  • Prevents condensation
  • Prevents corrosion by eliminating oxygen in the chamber

Explosion Resistant Interior/ Exterior for Hazardous Area

  • May be designed to meet NFPA 497 and National Electric Code, Article 500 standards

 Dry Air Dehumidification System

  • Dehumidifies chamber to dew point levels below those attainable by refrigeration systems.
  • Dehumidification coil

 Dry Air Purge System

  • Purges chamber of moisture and undesirable process vapors

 LN2 Boost Cooling System

  • Increases the rate or limit of cooling beyond refrigeration means.
  • Manual set flow adjustment valve

 CO2 Boost Cooling System

  • Increases the rate of cooling beyond refrigeration means.
  • Non-adjustable, carbon dioxide injecting port

its

40 and 64 cubic foot models

Model Non-
humidified
T40S-2T40C-4T40C-6T64S-7.5T64C-6T64C-15
HumidifiedT40RS-2T40RC-4T40RC-6T64RS-7.5T64RC-6T64RC-15
Workspace W 40(1016) 48(1219)
D 44(1118) 48(1219)
H 40(1016) 48(1219)
Exterior W 66(1676) 72(1829)
D 73.5(1867) 81.5(2070)
H 80.25(2038) 91(2311)

 

TemperatureNon-
humidified
T40S-2T40C-4T40C-6T64S-7.5T64C-6T64C-15
HumidifiedT40RS-2T40RC-4T40RC-6T64RS-7.5T64RC-6T64RC-15
Low C -40°C -73°C -73°C -40°C -73°C -73°C
High C +200°C +200°C +200°C +200°C +200°C +200°C
Humidity Capability 20% to 98% RH in the dry bulb range of +20°C or +85°C as limited by a 3°C dew point.

  Test data based on 24°C ambient, sea level, 60 Hz. On 50 Hz or higher than 24°C, ambient performance may be reduced. Consult factory regarding any special cooling requirements.

40 and 64 cubic foot models

Change Rates in Minutes
Time starting at Ambient to listed temperature. Based on empty chamber.
200°C
35 45
150°C
25 30
93°C
10 15
65°C
5 10
5 5
-18°C
20 10 10
-40°C
120 25 30
-54°C
45 40 45 20
-65°C
60 50 65 35

 

Live Load Capacity in Watts (Humidity System Off)
Temperature
+10°C            
-18°C 1000 4500
-40°C 100 1000
-54°C 1200 2000 1200 4000
-65°C 900 1500 800 2500

 

40 and 64 cubic foot models

Utilities, etc
Refrigeration (1) 2 HP (2) 2 HP (2) 3 HP (1) 7.5 HP (2) 3 HP (2) 7.5 HP
Heater Capacity 6 6 6 8 8 8
Humidifier KW 2 2 2 2 2 2
  GPH 1.0 1.0 1.0 1.0 1.0 1.0
AMPS

230V. 1Ph

230V. 1Ph 230V. 3Ph 230V. 3Ph 230V. 3Ph 230V. 3Ph
S & C RC & RS

41

50

50 50 38 46 71 80 57 65 71 80
Fuse

50

60

60

60 60 70 100 110 70 80 100 110
Unit Weight LBS.

2740

3540







View Mobile Site